5
Hardware Management
64
IPMI-over-LAN additional configuration steps
IfIPMIoverLANdoesnotworkafterperformingthebasicsteps:
1. Settheuserprivilegesforbothchannels:
rsysipmitoolI lan‐H<ShMgr_IP>Anone‐t<IPMB>userpriv142
rsysipmitool‐Ilan‐H<ShMgr_IP>‐Anone‐t<IPMB>userpriv242
2. Setthechannelandadministratoraccessforachannel:
rsysipmitool‐Ilan‐H<ShMgr_IP>Anone‐t<IPMB>raw060x40<channel>
0x420x44
rsysipmitool‐Ilan‐H<ShMgr_IP>‐Anone‐t<IPMB>raw060x40<channel>
0x820x84
rsysipmitool‐Ilan‐H<ShMgr_IP>‐Anone‐t<IPMB>channelgetaccess
<channel>01
rsysipmitool‐Ilan‐H<ShMgr_IP>
‐Anone‐t<IPMB>channelsetaccess
<channel>01ipmi=onlink=onprivilege=4
3. RepeatStep 2tosetaccesstotheotherchannel.
4. VerifyIPMIoverLANaccessbydisplayingtheSEL.
rsysipmitool‐Ilanplus‐H<IP>‐Anone‐C0sel
SELinformationshouldbedisplayed.IfthiscommanddoesnotdisplaySELinformation
orgivesanerror,seeIPMIoverLANtroubleshootingsteps.
5. RepeatStep 4toverifyaccesstotheIPaddressoftheotherchannel.
IPMI-over-LAN troubleshooting steps
1. Viewthecurrentsettingsforachannel:
rsysipmitool‐I<protocol>‐H<ShMgr_IP>‐Anone‐t<IPMB>lanprint
<channel>
2. VerifythattheIPaddressiscorrect.
3. VerifythatanonzeroMACaddressisset.
AMACaddressof00:00:00:00:00:00indicatestheEthernetcontrollerisnot
respondingtoqueries.ThiscanoccuriftheEthernetcontrollerdoesnothavethe
correctEEPROMfile.UpgradetheBaseEEPROMimageandthefront/rearEthernet
EEPROMimageusingtheimagefilesandinstructionsfromtheRadiSyssoftware
distribution.
4. Repeatsteps13tocheckthesettingsfortheotherchannel.